Home › Electrical Engineering Forum › General Discussion › WINDING FACTOR › Re: WINDING FACTOR
2010/12/22 at 8:43 am
#11692
Sarang
Participant
kw=kd*kp
kd:distribution factor can be determined by knowing the phase spread
kp:coil span factor by knowing the chording angle