    DEAR ENGINEERS

     

     CAN YOU GIVE ME A SUITABLE WAY TO CALCULATE THE KVA RATING OF A WELDING MACHINE HAVING NO NAME PLATE

     

    ALSO HOW CAN WE UNDERSTAND THE CAPACITOR CONNECTED IN COMBINATION WITH A POWER EQUIPEMENT IS PROPERLY WORKING?

    #12235
    Sunny Boy
    Participant

    Hi

    If there is a transformer in your welding machine you may calculate transformers power. I found one very approximate equation for calculating real power of a transformer.

    P=A*A, where A is cross section of transformers core.

     

    I usually test capacitors with current clamps. I use Fluke 345 which can actually measure the amount of active and reactive power consumed by a capacitor. You can compare measured data with data on capacitors nameplate.

    If you have ordinary clamp meter you may assume that all current is reactive. With use of reactive current, voltage and nominal capacity you can calculate actual reactive power of capacitor. But note that capacitors power is proportional to voltage squared (U*U).

     I hope that this information is useful.

     

    Best regards,

    Miha

    #12237
    admin
    Keymaster

    Sunny Boy said:

    Hi

    If there is a transformer in your welding machine you may calculate transformers power. I found one very approximate equation for calculating real power of a transformer.

    P=A*A, where A is cross section of transformers core.

     

    I usually test capacitors with current clamps. I use Fluke 345 which can actually measure the amount of active and reactive power consumed by a capacitor. You can compare measured data with data on capacitors nameplate.

    If you have ordinary clamp meter you may assume that all current is reactive. With use of reactive current, voltage and nominal capacity you can calculate actual reactive power of capacitor. But note that capacitors power is proportional to voltage squared (U*U).

     I hope that this information is useful.

     

    Best regards,

    Miha


    G S DAS said:

    DEAR ENGINEERS

     

     CAN YOU GIVE ME A SUITABLE WAY TO CALCULATE THE KVA RATING OF A WELDING MACHINE HAVING NO NAME PLATE

     

    ALSO HOW CAN WE UNDERSTAND THE CAPACITOR CONNECTED IN COMBINATION WITH A POWER EQUIPEMENT IS PROPERLY WORKING?


    Measure the current and voltage.

    kVA = volts x amps. 1-phase

    kVA = 1.732 x volts x amps – 3-phase

    #12241
    ramzy2006
    Participant

    Dear

    For the above mentioned, the situation depend on if you have electric measuring instrument or not, if yes what you have then you can decide

    In a present of jus clamp meter you can measure the current and volt

    KVA =V*I

    If you have just multi-meter reading ohm and volt

    You can calculate the resistance of the welding machine direct=R

    Then

    KVA = V2/R

    #12547
    admin
    Keymaster

    Welding Machine commonly rated in amperes. And most of welding machine have 50V secondary winding or use a volt meter to measure it exactly. To calculate the kVA=(ampere rating x secondary voltage) / 1000.