Servo-control of the current at the start of an electrical machine

This article has been proposed by a member of the community, it’s mostly a theoretical article about control systems for industrial control and automatism, thus not so close to our usual topics. A good lightweight subject to relax!

I am a young engineering student in France. I study automatic principles that can allow the servo-control of industrial processes. I’ve lately worked on electrical machines servo-control, such as brushed DC electric motor, synchronous and asynchronous electric motor, widely used nowadays in the industry. The purpose is to use correctors such as PI (Proportional Integrator) to adjust the servo-control of brushed DC electric motor. To do this, we often try to reduce the response time of the controller so that it can be neglected to the system mechanical dynamic’s, and so, can be assimilated to a gain, and not to a transfer function anymore, to simplify our studies.

I am wondering if those theoretical principles, effective in simulation (for example in Simulink or Matlab), are currently functioning nowadays in the industry?

Take the case of a brushed DC electric motor (BDCEM) that supplies a mechanical system. BDCEM used to be the most widespread electromechanical actuator for many applications like electric motor drive or applications for variable speed (high performances servomechanism of machine tools and robots).
Since a few years, BDCEM has been abandoned in many fields because of its high manufacturing cost, its significant maintenance (with the collectors) and the appearance of alternative moto-variator groups, said to be more efficient.
In your opinion, could it be possible, with an adaptive servo-control, to come back to BDCEM (that keeps an important place in industrial applications which need good positioning and precision)?

Without servo-control, we have obtained:

electrical engineering

Indeed it was a high current in the motor when starting. On a long term perspective, the frequent power-on/power-off were very bad for the motor, and could lead to its wear or even to its destruction.

Thanks to the equations of BDCEM, we can draw the following block diagram:

electrical engineering

Replacing the diagram in a closed-loop controller of the current, we obtain:

electrical engineering

In this example, the electric constant time is L/R = 3ms and the mechanical one is J/F = 65ms. The electric constant time is smaller than the mechanical one. So, we can consider that during machine’s making out current, the system linking the applied voltage to the current is a first order system. Current deformation (due to mechanical constant time) can be assimilated to a perturbation during the making-out time of the current.

electrical engineering

For the current closed-loop controller study, motor’s mechanical constant time can be neglected during the first instants. We obtain a first order system that can be adjusted with the traditional method of PI corrector (Ti and Kpi). So that, we obtain in simulation:
NB : In order to correctly visualize the different variables on the same graph, it has been necessary to put a gain of 1/10 for the voltage.

electrical engineering

A high voltage is observed at the machine’s starting up, but it does not last. That is because that current is equal to zero at the start of the machine while system has the instruction of a current with a not null value. So that, the system reacts increasing the voltage. Finally we obtain a good curve of the current, without overflow.

So, if this type of system is working in simulation, what really happens in reality?

And if it is a success, why don’t we come back to those old brushed DC electric motor?

6 Comments

  • Hi,

    We are from a print magazine for engineering students of India. We would like to publish this article in our issue. please contact ASAP

  • Modern controllers may incorporate both power electronics and microprocessors enabling the control box to take on many more tasks and to carry them out with greater precision.

  • Speed control in brushed DC motors used to be accomplished by varying the supply voltage using lossy rheostats to drop the voltage. The speed of shunt wound DC motors can also be controlled by field weakening. Nowadays electronic voltage control is employed.

  • Contemporary remotes may integrate both power gadgets and micro-processors allowing the management box to take on many more projects and to bring them out with higher accurate.

  • That is because that present is similar to zero at the start of it while program has the training of a present with a not zero value. So that, the program responds improving the current. Lastly we a great bend of the present, without flood.

  • Very useful information you mention in your post. How and when we should use electrician.

Leave a Comment