Should I replace my electrical system?

Last time, Pablo, a member of our community did a comparison between old and new electrical installations. This time he will analyze what are the most common problems encountered in electrical installations and how to solve them in order to get a better installation.

Enjoy and you too send us articles by mail if you want to be published on the blog!



Among the most common problems, you can find:

Circuit breaker that triggers very often

There are several causes; poor design of the electrical system that causes the circuit demand is greater than the capacity of the breakers, also the end of the useful life of the interrupter. Likewise corrosion, dust, animals can cause hot spots and thus the trip; serious problems of earth leakage currents and other causes.

Circuit breaker that triggers

How to fix it?

The most common way is to replace the breaker with a new one or in suitable conditions appropriate according to the characteristics of the panel.
If the problem is the breaker itself then the problem will be solved this way, otherwise we must examine other causes. It is important to remember that an electrical installation should be treated as a system in which the failure of one of its parts can bring down the system, so you should not only focus on replacing the breaker or any other electrical product, rather do a complete inspection of the facility.


A tingling sensation when touching an appliance, receptacle or switch

electrical-appliance-tingling-sensation

The cause is due to several factors, some equipment or circuit has problems of insulation and conducts current to ground, as well not exist GFCI devices to open the circuit and prevent the risk condition. Also a cause could be that there is no effective grounding conductor. This condition may increase the risk of electrocution in wet areas such as kitchens and bathrooms.

How to fix it?

First you must find the cause and fix the problem, either insulation in poor conditions or equipment. Then the installation must be improved to prevent future occurrence, guaranteed the correct operation of GFCI devices and effective grounding conductors.


Uncovered outlets and switch boxes

This is one of the most serious problems for people who have children and pets because they are at very high risk of electrocution.

uncovered-outlets-switch-boxes

How to fix it?

Fortunately the solution is very cheap, spend a few dollars or cents to buy and install new coverage.


Lights flicker

lights flicker
This can be caused by a bad electrical design that result in voltage drops above the maximum permitted, also may be due to problems in insulation of the conductors that cause short circuit. Other causes are poorly fasteners tight in the case of bare conductors.

How to fix it?

If the problem is the main feeder you should contact the electric company and report incident. Is more complicated when it comes to poor design, the solution is to improve the installation changing all the wiring.


Circuit breakers and panels with more conductors than allowed

This is a very common problem that I have met on many occasions. 2 or more (up to 8) conductors connected to the same switch or terminal lug, which is a violation of the rules, since generally the maximum number allowed is 2 (indicated on the breaker or panel). The main problem is a tightening without the necessary torque, causing hot spots in the connection.

How to fix it?

The solution is to add another panel or replace existing for another with the appropriate number of circuits.


Ungrounded receptacles

ungrounded-receptacles
The main problem is associated with lack of connection of the equipment to the effective grounding conductor which has an effect on the risk of electrocution and power quality in case that the equipment requires a path for harmonic currents.

How to fix it?

It can be fixed by changing all outlets and adding the effective grounding conductor. When it is not possible due to a high cost or because it is a construction with embedded wiring you can choose to install GFCI outlets. However in this case it should be considered the equipment does not necessarily need a path of grounding.



While it is true that there are other problems related to old installations, I believe that the above cover the most frequent. It would be interesting to know that other solutions can be offered to some of the problems mentioned and other problems that you think have a high frequency of occurrence.

Pablo. M



What do you think about Pablo’s review? Do you know other way to fix those common problems? What other problems do you know?