Eco-design of electric motors: two more steps to overcome in 2015 and 2017

The electric motors used in industrial and commercial sectors are improving their performance, in order to comply to the regulation under the EU directive for eco-design. Next levels to reach in 2015 and 2017.

According to international standard IEC 60034, three-phase induction motors (caged and single speed), were previously grouped into classes of efficiency:

EFF1 – high efficiency motor;
– EFF2 – increased efficiency motor;
EFF3 – standard motor.

Today, IEC 60034 is amended by section 30 (IEC 60034-30: efficiency classes for three-phase induction motors single speed cage (IE code)). It offers an internationally unified standard that distinguishes the low-voltage induction motors according to new efficiency classes (see Figure 1):

– IE3 – premium-efficiency motor;
– IE2 – high efficiency motor;
– IE1 – standard efficiency motor.

This classification replaces the efficiency classes EFF, NEMA / existing EPAct. It now covers three-phase motors, bipolar to 6-pole, from 0.75 to 375 kW and for maximum voltages of 1 000 V. First observation: the scope of the regulation is broader than before. Previously, only motors from 1.1 to 90 kW were concerned and for a nominal voltage up to 400V. Now, geared motors are included, but the servo motors remain excluded. Another advantage: the numerical sequence of these performance levels (this time logical!) will help to introduce in the future a class IE4 or IE5 even more demanding. Indeed, some manufacturers offering high performance motors begin to communicate informally about those future classes.

Calendar in 3 steps

Article 3 of Regulation 640/2009, implemented as part of the European Ecodesign Directive 2005/32/EC, imposes those classes according to a specific calendar.

– Since June 16, 2011: motors must have a efficiency greater than or equal to IE2 efficiency level;

– From 1 January 2015 : motors a nominal power of between 7.5 and 375 kW must or have an efficiency greater than or equal to the IE3 efficiency level, or meet the IE2 efficiency level and being equipped with a variable speed;

-From 1 January 2017 : all motors with a nominal power of between 0.75 and 375 kW must or have an efficiency greater than or equal to the IE3 efficiency level, or meet the IE2 efficiency level and being equipped with a variable speed drive.

Overall objective for the European Commission: to reduce by 135 TW the electricity consumption in EU 27 by 2020.

What technical and economic balance?

This directive will result that their equipment will move up market. The Capiel (Coordinating committee of associations of manufacturers of industrial electrical equipment of the EU) considers that these requirements lead to an increased purchase cost of the motor. An overinvestment that should be compensated by energy savings obtained over the life of the motor. Thus, the cost of ownership of high efficiency motor on the whole life cycle should be much lower. Because on its lifetime, the cost of ownership of a motor is composed of the energy cost for more than 80%! (see Figure 2).

 

Total cost of ownership of a motor on its entire lifecycle. Example of two motors IE1 used 4000 h / year at a loading rate of 60% for 12 years for 1.1 kilowatts and 11 kilowatts for 15 years.

 

Electrical efficiency: not to forget the notion of system

However, the Capiel highlights a defect with the new regulation. Indeed, by only setting to products (phase asynchronous motors) a minimum energy efficiency performance, the text do not take into account other system components (speed, starter, gear …). Hence the need, as Capiel, of a more global approach, incorporating the motor into the complete drive system.

 

 

 

 

 

 

 

 

 

6 Comments

  • similar to this web page your site is individual of my new favorites.I like this website shown in addition to it has given me several sort of inspiration to have success for certain reason, so thanks.

  • I Really Enjoyed The Blog. I Have Just Bookmarked. I Am Regular Visitor Of Your Website I Will Share It With My Friends Thanks and I promises I will visit your blog again.

  • Howdy, I do think your web site may be having web browser compatibility problems.
    When I look at your web site in Safari, it looks fine however when
    opening in IE, it has some overlapping issues.
    I just wanted to provide you with a quick
    heads up! Aside from that, excellent blog!

  • I really like that blog post..There are collection of amezing information about the electrical engineering..

  • First off I want to say awesome blog! I had a quick question in which I’d like
    to ask if you don’t mind. I was curious to find out how you center yourself and clear
    your head prior to writing. I’ve had trouble clearing my thoughts
    in getting my ideas out there. I do take pleasure in writing but it just seems like
    the first 10 to 15 minutes are generally lost just trying to figure out how
    to begin. Any ideas or tips? Thanks!

Leave a Comment