Archive for the ‘iec standard’ Category

Electrical Installation Guide 2016 – FREE Download Now

February 22nd, 2016 | 5 Comments | Posted in iec standard
Tags: , ,

electrical installation guide 2016
To you all Electrical Engineering Community blog members, good news!

Year 2016 has just begun, and yet we can already make you take advantage of an exclusive document for free!

This document is the fresh new edition of the Electrical Installation Guide (EIG), usually sold 60 euros and that you can DOWNLOAD here NOW and FOR FREE.

(more…)

Electrical Installation Guide 2015 – New version – FREE Download Now

January 21st, 2015 | Make a comment | Posted in iec standard
Tags: , ,

Electrical Installation Guide 2015

Designer, Consultant, Contractor, Panel builder, Facility manager, Student, teacher, Standardisation or certification experts… we all have to know and comply to electrical installation standards and regulations, in order to ensure the safety (and more and more the energy efficiency) of our customers’ electrical installations.

These international standards, set by the IEC, are complex and keep evolving; as a result, we struggled to stay informed.

As an example, are you aware that the IEC 60364 “Low-voltage electrical installations” part 4-42 “Protection for safety – Protection against thermal effects” has been updated in 2014, and that in particular it now includes recommendations for arc fault protection?

(more…)

Types of Earthing (as per IEC Standards)

May 31st, 2013 | 10 Comments | Posted in iec standard
Tags: , ,

Introduction

In the preceding article we studied the basics of Earthing and also the basic most Earthing type where the neutral is grounded at source and optionally grounding is done even at customer side.

Besides this, International Standard – IEC 60364 formally defines different types of Earthing arrangements. Let us examine them here in detail.

(more…)

Earthing system design

January 22nd, 2010 | 47 Comments | Posted in iec standard
Tags: , , ,

Electrical protection and lightning protection

I have a query on earthing system design. One designer has submitted me an earthing plan which interconnects the earth electrodes meant for equipment earthing and those for lightning protection purposes. By combining the earth electrodes he achieves overall earth resistance below one ohm required by IS 3043 (Indian standard).  But my question is whether this is an acceptable practice followed by industry or the earth electrodes of the two systems (protective earthing and lightning protection) can not be combined this way?
Would appreciate feedback. thanks in advance. 
D. Sunil 

(more…)

Electrical engineering Community is proudly powered by WordPress